![flexlm error 18 flexlm error 18](https://amazingclever524.weebly.com/uploads/1/2/6/6/126691324/274339126.png)
- #FLEXLM ERROR 18 LICENSE KEY#
- #FLEXLM ERROR 18 SOFTWARE#
- #FLEXLM ERROR 18 PC#
- #FLEXLM ERROR 18 LICENSE#
If one second (1000000 µs) is insufficient, you can try a higher value but consider the possibility that something else may be wrong.
#FLEXLM ERROR 18 LICENSE#
The tools were able to connect to the license server successfully. The new system variable is permanent you will not need to create it again when you reboot the system. FlexNet licensing error -18: License server system does not support this feature. Don't use separators when entering the value - 1000000, not 1,000,000 or 1.000.000 or 1 000 000.Ĭlick OK to close the New System Variable window, OK to close Environment Variables, and OK to close System Properties. We recommend 1000000 (a one and six zeroes), meaning 1 second. Log in to Windows as an administrator to perform this procedure.)Įnter the variable name FLEXLM_TIMEOUT and the new timeout value in microseconds. (If the System variables section is greyed out, you don't have administrator rights. In the dialog that appears, click the Advanced tab, and then the Environment Variables button.Ĭlick anywhere in the System Variables area and click New. (In Windows 7, 8, or 10, click Advanced System Settings when the System window appears.)
#FLEXLM ERROR 18 PC#
Right click on the This PC or My Computer icon and select Properties. Please follow this procedure on each user's computer that experiences the problem: The FLEXnet 11.10 License Administration Guide says that this procedure "Sets the timeout value a Fle圎nabled application uses when attempting to connect to a license server port in the range 27000–27009.") (Note: The procedure in this article may not be effective if you have specified an Lmgrd port number below 27000 or above 27009. You can increase this timeout value by setting a system environment variable.
![flexlm error 18 flexlm error 18](https://s3.manualzz.com/store/data/025834336_1-18e08fb2e6aa505ff511e326c0b723cc-360x466.png)
Note that the compiler and elaborator don't look for a licence, it's only when you try to run simulation that the licence is checkd for, so Muffi's question is. Likewise, if the client is connecting to the server through a VPN and network performance is slow, the license request may time out. You could also try doing 'setenv FLEXLMDIAGNOSTICS 3' before trying to run the simulation, this should result in detailed messages about how the simulator is trying to find the licence. If there are a lot of Internet "hops" between the user and the FLEXlm license server, that may not be enough time for the required handshaking to authorize the user. The default FLEXlm License Manager timeout is 0.1 second. We have a FLEXlm license on our VPN or other wide area network, but our users are getting error -15,570 or "Unable to reach a network server" when they try to launch the software. FLEXlm License Manager Times Out (Error -15,570)ĭisponible en español: Tiempo de Espera en el Administrador de Licencias FLEXlm (Error -15,570)Īpplies to: All products with a Concurrent Network license The FLEXlm -18 error should now be resolved and you should be able to use the IBM Rational product successfully.FLEXlm License Manager Times Out (Error -15,570)ġ8.15.